This piece describes a method of performing minimally invasive mitral valve repair surgery through a lower mini-sternotomy.
Operative Steps
![[Illustration: Figure 1]](https://ctsnet.freelock.com/wp-content/uploads/2008/05/4298_01t.jpg)
![[Illustration: Figure 2]](https://ctsnet.freelock.com/wp-content/uploads/2008/05/4298_02t.jpg)
The cannulation technique is as follows: The ascending aorta is cannulated with a Sarns® 20 FR flexible cannula. ![[Illustration: Figure 3]](https://ctsnet.freelock.com/wp-content/uploads/2008/05/4298_03t.jpg)
![[Illustration: Figure 4]](https://ctsnet.freelock.com/wp-content/uploads/2008/05/4298_04t.jpg)
After cardiopulmonary bypass is established, the patient is cooled systemically to 28° C. The aorta is cross-clamped with an atraumatic clamp and cardiac arrest is achieved with cold blood cardioplegia in the![[Illustration: Figure 5a]](https://ctsnet.freelock.com/wp-content/uploads/2008/05/4298_05at.jpg)
The fossa ovalis is exposed and incised.
The left heart is decompressed. ![[Illustration: Figure 5b]](https://ctsnet.freelock.com/wp-content/uploads/2008/05/4298_05bt.jpg)
Once the septum is opened and the retraction system has been set, anterior traction on the atrial septum is accomplished by a blade retractor from the Cosgrove retractor system to expose the mitral valve. To facilitate the exposure, coronary suckers or hand held flexible retractors can be used to move the left atrium to the right. Placing annuloplasty sutures in the posterior annulus and pulling these rightward may also help to expose the posterior annulus.
Mitral valve repair is then carried out in the usual fashion. In the case shown, P2 has ruptured chordae and is resected. Leaflet advancement is carried out with a running 4-0 Prolene® and then attachment of the two parts of the leaflet are put together with another running 4-0 Prolene® as well.
![[Illustration: Figure 7]](https://ctsnet.freelock.com/wp-content/uploads/2008/05/4298_07t.jpg)
Interrupted 2-0 multifilament mattress sutures beginning at the fibrous trigone and proceeding around the posterior annulus are placed through the ring. The handle is released and the annuloplasty ring slid into position. The sutures are tied and cut and the stent is removed leaving the annuloplasty ring in place. ![[Illustration: Figure 8]](https://ctsnet.freelock.com/wp-content/uploads/2008/05/4298_08t.jpg)
The septal incision in the left atrium is closed using a continuous running 4-0 Prolene. Prior to the tying the last suture, air is removed by inflating the lungs. The aortic cross clamp is then removed and any residual air is removed by inflating the lungs and filling the left ventricle with blood and gentle suction through the cardioplegia site in the ascending aorta.
A pacing wire is placed on the anterior right ventricle prior to removal of the cross-clamp while the heart is decompressed so as to have good visualization of its placement.
After the cardiac function has been restored and the pacemaker wires brought out through the skin, two chest tubes are placed in the right chest and one in the pericardial cavity. The wound is closed in layers with stainless steel wire for the sternum, then layers of absorbable suture for the subcutaneous and fascia layers.
Preference Card
- DEBAKEY ILIAC CLAMPS
- CANNULAS
- COSGROVE EDWARDS ANNULOPLASTY RING
- KOROS SLIDING CAB RETRACT
Tips & Pitfalls
Safe cannulation will depend on the space available in the chest. In the vast majority of cases intrathoracic cannulation will be possible. If the femoral artery/femoral vein approach is chosen; the technique has been modified using 5cm supra inguinal ligament incision parallel to the inguinal ligament which has minimal wound complications. When the femoral artery/femoral vein is exposed purse string sutures are placed and the Seldinger technique is used to insert the cannulae rather than clamping and incising the vessels.
Placement of the annuloplasty sutures before repairing the valve helps by pulling the valve into the incision, increasing exposure.
References
Cohn LH. Mitral valve repair. Oper Tech Card Thorac Surg. 1998;3:109-25.
Aklog L, Adams DH, Couper GS, Gobezie R, Sears S, Cohn LH. Techniques and results of direct-access minimally invasive mitral valve surgery: A paradigm for the future. J Thorac Cardiovasc Surg 1998;116:705-15.
Byrne JG, Mitchell ME, Adams DH, Couper GS, Aranki SF, Cohn LH. Minimally invasive direct access mitral valve surgery. Seminars in Thoracic and Cardiovascular Surgery Vol 11, No 3 (July), 1999:212-22.
Cosgrove D, Aricidi J, Rodriguez et al: Initial experience with the Cosgrove-Edwards annuloplasty system. Ann Thorac Surg 60:499-504, 1995.


![[Illustration: Figure 6]](https://ctsnet.freelock.com/wp-content/uploads/2008/05/4298_06t.jpg)